4.2 | Signals and Noise | ||
| 4.2.8 | Testing optical fiber |
|
A fiber link consists of two separate
glass fibers functioning as independent data pathways.
One fiber carries transmitted signals in one direction, while the
second carries signals in the opposite direction. Each glass fiber is
surrounded by a sheath that light cannot pass through, so there are no
crosstalk problems on fiber optic cable. External
electromagnetic
interference or noise has no affect on fiber cabling. Attenuation does
occur on fiber links, but to a lesser extent than on copper cabling.
Fiber links are subject to the optical
equivalent of UTP impedance discontinuities.
Because noise is not an issue when transmitting on optical fiber, the main concern with a fiber link is the strength of the light signal that arrives at the receiver. If attenuation weakens the light signal at the receiver, then data errors will result. Testing fiber optic cable primarily involves shining a light down the fiber and measuring whether a sufficient amount of light reaches the receiver. On a fiber optic link, the acceptable
amount of signal power loss that can occur without dropping below the
requirements of the receiver must be calculated. This calculation is
referred to as the optical link loss budget. A fiber test instrument
checks whether the optical link loss budget has been exceeded.
|